Region: 2 State: SC
Unit: [1] [ ] [ ]
RX Type: [1] W-3-LP,[2] W-AP1000,[3] W-AP1000
NRC Notified By: MICHAEL MOORE
HQ OPS Officer: DONG HWA PARK
Notification Date: 09/14/2016
Notification Time: 01:02 [ET]
Event Date: 09/13/2016
Event Time: 20:30 [EDT]
Last Update Date: 09/14/2016
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(D) – ACCIDENT MITIGATION
Person (Organization):
SHAKUR WALKER (R2DO)

Unit SCRAM Code RX CRIT Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation

…read more